Comparison RG58
The following overview allows you to compare the technical data of the RG58 with various versions of the RG58 from our online shop at a glance.
Cable Comparison RG58
Cable comparison | |||||||
Designation | RG 58 C/U | RG 058 C/U | RG 58 LSNH | RG 58 PUR | |||
Article number [Shop] | 050244 | 050240 | 050235 | 050168 | |||
Datasheet/pdf | (246 KB) | (256 KB) | (118 KB) | (91 KB) | |||
Shield type | single shielded | single shielded | double shielded | single shielded | |||
Technical Data – cable construction | |||||||
Outer sheath |
Ø 5 mm
|
Ø 5 mm
|
Ø 5 mm
|
Ø 5 mm
| |||
Sheath material |
PVC
|
PVC
|
FRNC / LSNH
|
PUR
| |||
Sheath colour | black | black | black | black | |||
Diameter Dielectric [Ø/mm] |
Ø 2.95 mm
|
Ø 2.95 mm
|
Ø 2.95 mm
|
| |||
Dielectric |
PE
|
PE
|
PE
|
PE
| |||
Inner conductor [Ø/mm] |
19 x Ø 0.18 mm
|
19 x Ø 0.18 mm
|
19 x Ø 0.18 mm
|
19 x Ø 0.18 mm
| |||
Inner conductor material | Tinned copper stranded wire | Tinned copper stranded wire | Tinned copper stranded wire | Tinned copper stranded wire | |||
Electrical values | |||||||
Impedance [Ω] |
50
|
50
|
50
|
50
| |||
Frequency max.[Ghz] |
1
|
2
|
3
|
1
| |||
Capacitance [p/m] |
100
|
100
|
67
|
100
| |||
Shielding dimension [dB/m] |
57
|
57
|
90
|
38
| |||
Max. voltage [V] |
|
|
|
2000
| |||
Attenuation values at different frequencies | |||||||
Attenuation at 400MHz [dB/m] |
0.3
|
0.3
|
0.28
|
0.3
| |||
Attenuation at 1000MHz [dB/m] |
0.52
|
0.52
|
0.48
|
0.52
| |||
Attenuation at 2000MHz [dB/m] |
|
|
0.73
|
| |||
Other parameters | |||||||
Temperature [max.°C] |
70
|
70
|
70
|
80
| |||
[min.°C] |
-30
|
-30
|
-30
|
-40
| |||
Weight [kg/m] |
0.04
|
0.037
|
0.041
|
0.038
| |||
More information | |||||||
Infos | Link | Link | Link | Link |